Technical data

Digital laser measure

Advanced
Distance 50C

Advanced
Distance 60C

Article number

‎3 603 F72 2..‎

‎3 603 F72 E..‎

Measuring rangeA)

0.05–50 m

0.05−60 m

Measuring accuracyB)

±2.0 mm

±2.0 mm

Operating temperature

−10 °C to
+50 °C

−10 °C to
+50 °C

Storage temperature

−20 °C to
+70 °C

−20 °C to
+70 °C

Relative air humidity max.

90 %

90 %

Max. altitude

2000 m

2000 m

Pollution degree according to IEC 61010-1

2C)

2C)

Laser class

2

2

Laser type

635 nm,
< 1 mW

635 nm,
< 1 mW

Divergence of the laser beam

< 1.5 mrad (full angle)

< 1.5 mrad (full angle)

Automatic switch-off after approx.

  • Laser

20 s

20 s

  • Measuring tool (without measurement)

5 min

5 min

Batteries

3 × 1.5 V LR03 (AAA)

3 × 1.5 V LR03 (AAA)

Weight according to EPTA-Procedure 01:2014

0.13 kg

0.13 kg

Dimensions

115 × 50 × 23 mm

115 × 50 × 23 mm

Battery life approx.

  • Individual measurementD)E)

10,000

10,000

  • Continuous measurementD)E)

2.5 h

2.5 h

Grade measurement

Measuring range

0°–360° (4 × 90°)

0°–360° (4 × 90°)

Measuring accuracyE)F)

±0.2°

±0.2°

Smallest display unit

0.1°

0.1°

Data transmission

Bluetooth®

Bluetooth®
Low EnergyG)

Bluetooth®
Low EnergyG)

Operating frequency range

2402–2480 MHz

2402–2480 MHz

Max. transmission power

2.5 mW

2.5 mW

A)

When measuring from front edge. In unfavourable conditions such as very strong lighting, a temperature greatly deviating from 20 °C or a poorly reflecting surface, the measuring range can be restricted.

B)

This applies for high reflectivity of the target (e.g. wall painted white), weak background lighting and a 20 °C operating temperature. In addition a deviation of ±0.05 mm/m needs to be taken into account. In unfavourable conditions such as strong lighting, high altitudes or a poorly reflecting surface, and at a 20 °C operating temperature, the deviation can be ±4 mm. In addition, a deviation of ±0.15 mm/m must be taken into account.

C)

Only non-conductive deposits occur, whereby occasional temporary conductivity caused by condensation is expected.

D)

Bluetooth® deactivated

E)

At an operating temperature of 20 °C

F)

After user calibration at 0° and 90°; An additional grade error of ±0.01°/degree to 45° (max.) has to be taken into account. The left-hand side of the measuring tool serves as the reference level for grade measurement.

G)

When using Bluetooth® Low Energy devices, it may not be possible to establish a connection depending on the model and operating system. Bluetooth® tools must support the GATT profile.

The serial number (6) on the type plate is used to clearly identify your measuring tool.