"Error" in the Display
"Error" indicator and "----" in the display
Cause: Angle between laser beam and target is too sharp
Corrective measure: Increase the angle between the laser beam and target
Cause: Target surface is reflecting too strongly (e.g. mirror) or too weakly (e.g. black material), or ambient light is too strong
Corrective measure: Use a laser target plate (accessory)
Cause: Laser beam output (13) or reception lens (12) is fogged up (e.g. due to rapid temperature change)
Corrective measure: Rub the laser beam output (13) or the reception lens (12) dry with a soft cloth
Cause: Calculated value is larger than 999.999 or smaller than –999.999 m/m²/m³
Corrective measure: Split the calculation into intermediate steps